• Contact us
  • Career
  • Terms and Conditions
  • Payment form
  • DE
  • EN
  • CN

Black cat logo Langer EMV-Technik

  • About us
    • Company
      • Career
      • Terms and Conditions
      • Company Profile
      • Milestones
    • Distributors
      • Asia
      • Europe
      • North America
    • Contact us
    • Map and Travel Information
    • Sponsoring
    • Events
    • Payment form
  • Products
    • PCB Immunity
      • Immunity Development System
      • Mini Burst Field Generators
      • Accessory EFT/Burst generators IEC 61000-4-4
      • Optical Signal Transmission
      • Burstdetector
    • PCB Emission
      • Measurement Technology for the Development Stage
      • Near-Field Probes
      • Preamplifier
      • Near-Field Microprobes
      • Optical Signal Transmission
    • IC Test System
      • IC Test Environment
      • Emission
      • Immunity
      • Simulation
    • IC Security
      • Fault Injection
      • Side-channel analysis
      • Positioning systems
    • Positioning Systems
      • Langer Scanner
      • Accessories for Langer Scanner
      • Near-field Scanner Probes
    • Software
      • CS-Scanner, ChipScan-Scanner Software / USB
      • CS-ESA set, ChipScan-ESA Software / USB
    • Measuring and Calibration Stations
      • PCB
      • IC
      • Connector
    • Equipment for Teaching and Training
      • EMC-Basic 1 set, Demonstration Boards Mini Burst Field Generators
      • EMC-Basic 2 set, Demonstration Boards Near-Field Probes
      • DB 20 set, Demo Board 20
      • D10 set, EMC Demonstration Board
  • Seminars
    • SF-GE, Experimental EMC Seminar - Interference Immunity - Basics & Troubleshooting (3 days)
    • SA-GE, Experimental EMC Seminar - Interference Emission - Basics and Troubleshooting (3 days)
    • SF IHS, Experimental EMC In-house Seminar - Immunity 3 days
    • SA IHS, Experimental EMC In-house Seminar - Emission 3 days
    • Dates Overview
  • Services
    • EMC Workshops
    • IC-EMC Analysis
      • Emission
      • Immunity
    • EMC Analysis
      • SMM Langer, Measuring of electromagnetic Shielding according to Langer method
      • COCI, Measurement of the Coupling Inductance of Connectors and Cables
    • EMV-B, EMC-Consulting / Hour
  • EMC Know-How
    • Downloads
    • Technical article Board-EMC
      • Basic Knowledge
      • Immunity
      • Emission
    • Technical article IC-EMC
      • Basic Knowledge
      • Immunity
      • Emission
    • Langer EMV-Technik in scientific research
    • Newsletter
      • 17 ESA1 set
      • 16 ICI-DP sets
      • 15 tent and GP 23 set
      • 14 Mini Burst Field Generators in pocket size
      • 13 Achieve interference immunity by identifying and eliminating EMC weak points:
      • 12 ICR: Near-field analysis in the micrometer range and its advantages
      • 11 ChipSan-ESA now supports more measuring devices
      • 10 P512 and DPI
      • 09 Surface Scan on IC Level with high Resolution
      • 08 ESD and Efficient Electronic Design
      • 07 EMC Measurement Technology for Testing Integrated Circuits - An Introduction
      • 06 Measuring the Shielding Effectiveness at IC Level with the IC Test System P1402/P1502
      • 05 Time and cost savings when recording and documenting RF measurements with a spectrum analyzer
      • 04 Radiated Emissions at the PCB Level - An Introduction
      • 03 Interference suppression on a direct-current motor controlled by PWM
      • 02 XF sniffer probes and LVDS suppression
      • 01 MFA micro probes and LVDS suppression
    • Videos
      • How-to videos
      • EMC Webinar
  • PCB Immunity
  • PCB Emission
    • Measurement Technology for the Development Stage
    • Near-Field Probes
      • LF, Passive, 100 kHz up to 50 MHz
      • RF, Passive, 30 MHz up to 3 GHz
        • RF Basic setBasic set of near-field probes 30 MHz to 3 GHz
        • RF1 setNear-Field Probes 30 MHz up to 3 GHz
        • RF2 setNear-Field Probes 30 MHz up to 3 GHz
        • RF3 mini setNear-Field Probes 30 MHz up to 3 GHz
        • RF4-E setNear-Field Probes E-field 30 MHz up to 3 GHz
        • RF-R 400-1H-Field Probe 30 MHz up to 3 GHz
        • RF-R 50-1H-Field Probe 30 MHz up to 3 GHz
        • RF-R 3-2H-Field Probe 30 MHz up to 3 GHz
        • RF-R 0.3-3H-Field Probe mini 30 MHz up to 3 GHz
        • RF-B 50-1H-Field Probe 30 MHz up to 3 GHz
        • RF-B 3-2H-Field Probe 30 MHz up to 3 GHz
        • RF-B 0.3-3H-Field Probe mini 30 MHz up to 3 GHz
        • RF-U 5-2H-Field Probe 30 MHz up to 3 GHz
        • RF-U 2.5-2H-Field Probe 30 MHz up to 3 GHz
        • RF-K 7-4H-Field Probe 30 MHz up to 1 GHz
        • RF-E 02E-Field Probe 30 MHz up to 1.5 GHz
        • RF-E 03E-Field Probe 30 MHz up to 3 GHz
        • RF-E 04E-Field Probe 30 MHz up to 3 GHz
        • RF-E 05E-Field Probe 30 MHz up to 3 GHz
        • RF-E 09E-Field Probe 30 MHz up to 3 GHz
        • RF-E 10E-Field Probe 30 MHz up to 3 GHz
      • XF, Passive, 30 MHz up to 6 GHz
      • SX, Passive, 1GHz up to 20 GHz
      • HR, Passive, up to 40 GHz
      • MFA, Active, 1MHz up to 6 GHz
      • CM-SHPCustomized Shapes
      • Individual CharacterizationNear-Field Probe Characterization
    • Preamplifier
    • Near-Field Microprobes
    • Optical Signal Transmission
  • IC Test System
  • IC Security
  • Positioning Systems
  • Software
  • Measuring and Calibration Stations
  • Equipment for Teaching and Training
  • Products
  • PCB Emission
  • Near-Field Probes
  • RF, Passive, 30 MHz up to 3 GHz
  • Z23-1 set, Shielding Tent (900 x 500x 400) mm
  • BD 11, H-Field Burst Detector

BD 11

H-Field Burst Detector

  • Short description
  • Recommended products
  • Technical parameters
Send enquiry Datasheet
  • BD 11, H-Field Burst Detector
  • Application BD 11 with cable
    Application BD 11 with cable
BD 11, H-Field Burst Detector Application BD 11 with cable
  • BD 11, H-Field Burst Detector
  • Application BD 11 with cable
Short description

The BD 11 is designed for the detection of a burst- or ESD current pulse within a cable. It facilitates the finding the causes of sporadic errors within the system. The burst detector is small and handy. It is highly sensitive and steplessly variable.
The BD 11 detects the magetic field resulting from the burst current. Detected disturbing pulse are displayed via LED on the detector and can be led as signals via a relay output (potential free) or a fibre optic cable to different evaluation instruments (e.g. for recording or emergency stop of the controlled system). The pulse range is approx. 100ms. The BD 11 includes memory.

Technical parameters
Optical fibre connector 2.2 mm Ø
Supply voltage 2 x 1,5V AAA battery
Max. switching voltage 125 V
Max. switching current 1 A
Max. optical fibre length 20 m
Sizes (L x W x H) (88 x 85 x 32) mm
  • © Langer EMV-Technik
  • Contact us
  • Legal notice
  • Privacy policy
  • Sponsoring
  • YouTube
  • Linked-In
Europäischer Fonds für regionale Entwicklung EFRE - Europäischer Sozialfonds ESF