P1402 / P1502 set
RF Field Coupling up to 3 GHz
Short description
The RF magnetic field injection up to 3 GHz probe set tests the ICs in terms of their immunity under the influence of RF magnetic fields (P1402) or RF-E-field (P1502).
These analysises are the basis for an EMC compatible development of ICs. Furthermore, the detemined RF parameter are helpful for the IC user to develop optimal IC applications.
In addition to the test setup an ICE1 test environment, a RF generator and a power amplifier are needed.
Field sources can only be run in connection with a short circuit- and open circuit proof power amplifier.
Scope of delivery
- 1x P1402, RF Magnetic Field Source up to 3 GHz
- 1x P1502, RF E-Field Source up to 3 GHz
- 1x D70 h03, Spacer Ring, 3 mm
- 1x D70 h10, Spacer Ring, 10 mm
- 2x SMA-SMB 1 m, SMA-SMB Measuring Cable
- 1x FKE 30, Field Chamber Insert
- 1x P1402 / P1502 case, System Case
- 1x P1400 / P1500 m, P1401 / P1501 Set User Manual
Scope of delivery details
-
P1402
RF Magnetic Field Source up to 3 GHz
The P1402 RF magnetic field source tests the ICs in terms of their immunity under the influence of RF magnetic fields. The IC to be tested is tested while it is running. The P1402 magnetic field source is operated in connection with a power amplifier and a RF signal generator. * above 2 GHz the E-f…
-
P1502
RF E-Field Source up to 3 GHz
The P1502 RF E-field source tests the ICs in terms of their immunity under the influence of RF E-fields. The IC to be tested is tested while it is running. The P1502 E-field source is operated in connection with a power amplifier and a RF signal generator.