• Homepage
  • Company
  • Products
  • Consulting
  • Bibliography

P1202-4/1302-4 probes for EFT field injection based on IEC 61000-4-4

Application:
The probes are used to evaluate the immunity of ICs to direct injection of magnetic and electric field EFT pulses.
There are two versions available:

  • P1202-4 / P1302-4 (without inductive load)
  • P1202-4 R50 / P1302-4 50R (with inductive load)

The probes are positioned at a defined distance (3 or 10 mm) above the IC.

Property:

  • standard EFT pulse shape according IEC 61000-4-4

Technical parameters:

Probes:

P1202-4 / 50R

P1302-4 / 50R

Puls shape:

5 / 50 ns    

High voltage:

± 8 kV

Line impedance:

50 Ohm

Connection EFT generator:

50 Ohm Fischer plug socked (D103A023)

Measurement output:

50 Ohm, SMB

Shunt for current measurement:

0.1 Ohm

Termination:

50 Ohm - P1202-4 50R

50 Ohm - 1302-4 50R

Current / Voltage

correction factor R:

-26 dB Ohm

-60 dB Ohm

 

 

EFT H-field injection probes P1202-4 / P1202-4 50R:

EFT E-field injection probe P1302-4 / P1302-4 50R