P1202-4/1302-4 probes for EFT field injection based on IEC 61000-4-4

Application:
The probes are used to evaluate the immunity of ICs to direct injection of magnetic and electric field EFT pulses.
There are two versions available:
- P1202-4 / P1302-4 (without inductive load)
- P1202-4 R50 / P1302-4 50R (with inductive load)
The probes are positioned at a defined distance (3 or 10 mm) above the IC.
Property:
- standard EFT pulse shape according IEC 61000-4-4
Technical parameters:
Probes: | P1202-4 / 50R | P1302-4 / 50R |
Puls shape: | 5 / 50 ns | |
High voltage: | ± 8 kV | |
Line impedance: | 50 Ohm | |
Connection EFT generator: | 50 Ohm Fischer plug socked (D103A023) | |
Measurement output: | 50 Ohm, SMB | |
Shunt for current measurement: | 0.1 Ohm | |
Termination: | 50 Ohm - P1202-4 50R | 50 Ohm - 1302-4 50R |
Current / Voltage correction factor R: | -26 dB Ohm | -60 dB Ohm |