IC H-Field Probe 1601

Application:
Measuring magnetic near fields via IC. The voltage measured by the probe is a measure for emissions from the IC which were stimulated by the H-field.

Properties:
The probe has a 50 Ohm input which is connected to an H-field loop. The loop is pivoted, adjustable in height and exchangeable.

 

 

 

Technical parameters:

Transfer ratio of the voltagemeter:

0 dB

Input resistance:

1,5 Ohm

Internal bandwidth:

16 kHz - 3 GHz

Measuring range with H16-02 loop

120MHz - 3 GHz

RF output:

50 Ohm

-1 db Compression point:

120 dBµV

IP3:

27,0 dBm

Noise figure:

4,5 dB

Auxiliary power:

12 + -10% V

H-field loop dimension

30 mm x 20 mm

 

 

Probe 1601, H-field measuring
Probe 1601, H-field measuring at stripline

 