• Company
  • Products
  • Consulting
  • Bibliography

Burst

Burst power station BPS 201

The BPS 201 burst power station supplies and controls the probes.

The burst parameters are set from a PC via a serial interface.

 

- regulate the burst frequency and the burst voltage via software
- single pulse and pulse sequences

 


Technical parameters:


Burst frequency range:

0,1 Hz - 20 kHz

Burst voltage range:

depending on the connected probe
polarity: +/- or alternating

External trigger:

TTL, max. 16,6 kHz / connector: BNC

Trigger delay:

40 ns

Synchronization output:

TTL / connector: BNC

Control / signal output:

RS 232

Voltage supply:

12 V DC

Software

PC control software

 

Technical data  (pdf, 120 kb)

Characterizing the Immunity of Integrated Circuits  (pdf, 400 kb)


ESD

Burst power station BPS 203

The Burst power station BPS 203 supplies and controls the ESD probes (P331, P1201 and P1301). The BPS 203 is connected from the PC via USB and supported by software BPS 203-Client

- regulate the pulse frequency and the pulse voltage via software
- single pulse and pulse sequences


Technical parameters:


Pulse frequency range:

0,1 Hz - 30 Hz
(depending on the connected probe)

Pulse voltage range:

+/- 100 V bis +/-10,5 kV
(depending on the connected probe)
polarity: +/- or alternating

Control / signal output:

USB

Voltage supply:

12 V / 1A DC plug in power supply unit

Software

BPS 203-Client

 

Technical data  (pdf, 160 kb)