Technical data
System OSE 100
Transmission rate: | DC 10 Mbps |
Reachable space (fibre optic): | 1 - max. 20 m |
The OE 110 and OE 400 receivers are used in connection with:
- Sensors of the S 21, S 31 and S 32 Type for signal transmission via optical fibre
- Burst detectors of the BD 01 B, BD 01 E and BD 06 B Type for detection of burst processes
Receiver - System OSE 100
Transmission rate: | DC - 10 Mbps |
Power supply: | 12 Volt via external power supply unit |
Optical fibre connection: | ø 2,2 mm |
Receiver OE 110
Current input: | < 25 mA |
Pulse-width modulation: | 100 ms switch on |
Optical input: | Optical fibre ø 2,2 mm, plastic |
Output: | BNC-plug, 5 V HCMOS |
Receiver OE 400
Current input: | < 100 mA |
Pulse-width modulation: | 5 µ / 50 ms switch on |
Optical input: | 4x Optical fibre ø 2,2 mm, plastic |
Output: | 4x BNC-plug, 5 V HCMOS |
Sensors - System OSE 100
Transmission rate: | 2 - 10 Mbps |
Optical fibre connection : | ø 2.2 mm |
Sensor S 31
Dimensions (with plug-connector): | 34 x 10 x 9 mm |
Voltage supply: | 3 - 5 Volt |
Current input: | 10 mA |
Reference IC type: | 74_ _00 |
Sensor S 32
Dimensions (with plug-connector): | 34 x 10 x 9 mm |
Voltage supply: | 3 - 18 Volt |
Current input: | 2.5 - 16 mA |
Reference IC type: | 74__00 |
S 31 and S 32: The input IC that determines a sensor´s speed and sensitivity can be exchanged.